Home

Saturday, April 1, 2023

Marantz 2215 Receiver Restoration

Unit: AM/FM Stereo Receiver
Manufacturer: Marantz
Model: 2215
SN: 7972

Today I'm showcasing a Marantz 2215 vintage receiver that came in for restoration. This model was manufactured from 1971 to 1973. It produces 15 watts per channel into 8 ohms with no more than 0.9% total harmonic distortion. The retail price in 1971 was $199.00 (Ref. Stereo Review, November 1971, page 43). The optional walnut veneer cabinet for this model is WC-22/WC-42.

Marantz_2215_after restoration

An early version of the Marantz 2215 features a champagne engraved faceplate. Later versions have a brushed metal faceplate. I believe the champagne engraved faceplate was only installed in 1971. And in 1972, the champagne faceplate was replaced with a brushed faceplate to reduce the cost. 

I serviced another 2215 a few years ago with serial number 3835 and this receiver has the original champagne engraved faceplate. It was manufactured in 1971 according to the factory stamp on the chassis. This particular unit with serial number 7972 was manufactured in 1972 and has a brushed metal faceplate.

Power Supply Board (P800)

The power supply board has 7 aluminum electrolytic capacitors: C803, C804, C805, C806, C808, C809, and C810. I replaced all capacitors on this board with low impedance Nichicon UPW/UPM caps.

The original e-caps were tested with an Atlas ESR70 capacitance meter; the results are below.

Test results on original capacitors removed from the power supply board:

C803: rated capacitance – 330uF, measured – 383uF, ESR – 0.04Ω, deviation: +16%
C804: rated capacitance – 470uF, measured – 492uF, ESR – 0.05Ω, deviation: +5%
C805: rated capacitance – 470uF, measured – 553uF, ESR – 0.08Ω, deviation: +18%
C806: rated capacitance – 47uF, measured – 55uF, ESR – 0.24Ω, deviation: +17%
C808: rated capacitance – 47uF, measured – 57uF, ESR – 0.24Ω, deviation: +21%
C809: rated capacitance – 100uF, measured – 121uF, ESR – 0.11Ω, deviation: +21%
C810: rated capacitance – 470uF, measured – 563uF, ESR – 0.04Ω, deviation: +20%

To improve the reliability of the power supply board, I also replaced all semiconductors. 

The original regulating transistor 2SC1213A installed in position H802 was replaced with a new Fairchild KSC2383YTA transistor.

Two original diodes H804, H805, and H808 were replaced with the modern fast recovery rectifiers UF4005.

Finally, the original Zener diode BZ-120 installed in position H806 was replaced with a new OnSemi 1N4742A.

Power supply board - before and after

Marantz_2215_Power Supply Board (P800)_before servicing

Marantz_2215_Power Supply Board (P800)_after servicing

Tone Amplifier Board (P500)

The tone amplifier board has 4 low leakage e-caps (C505, C506, C513, C514) installed in the signal path, and 7 aluminum electrolytic capacitors (C503, C504, C509, C510, C511, C512, C515). 

The original low leakage e-caps were replaced with high-quality film polyester WIMA MKS2 caps. Two ordinary aluminum e-caps (C503, C504) installed in the signal path were replaced with modern low leakage Nichicon UKL caps to reduce the noise generated in the circuit. And the remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps.

Most of the original electrolytic capacitors from this board are outside the capacitance tolerance of +/- 20%. The original e-cap C510 has drifted from its nominal capacitance of 100uF to 295uF, i.e. the deviation is 195%!

Test results on original capacitors removed from the tone amplifier board:

C503: rated capacitance – 4.7uF, measured – 6.2uF, ESR – 1.61Ω, deviation: +32%
C504: rated capacitance – 4.7uF, measured – 6.1uF, ESR – 1.48Ω, deviation: +30%
C505: rated capacitance – 1uF, measured – 1uF, ESR – 7.1Ω, deviation: 0%
C506: rated capacitance – 1uF, measured – 1uF, ESR – 5.8Ω, deviation: 0%
C509: rated capacitance – 100uF, measured – 145uF, ESR – 0.27Ω, deviation: +45%
C510: rated capacitance – 100uF, measured – 295uF, ESR – 0.38Ω, deviation: 195% (!)
C511: rated capacitance – 10uF, measured – 12uF, ESR – 0.66Ω, deviation: +20%
C512: rated capacitance – 10uF, measured – 11uF, ESR – 0.69Ω, deviation: +10%
C513: rated capacitance – 0.47uF, measured – 0.73uF, ESR – N/A, deviation: +55%
C514: rated capacitance – 0.47uF, measured – 0.68uF, ESR – N/A, deviation: +45%
C515: rated capacitance – 100uF, measured – 123uF, ESR – 0.12Ω, deviation: +23%

The NPN transistor 2SC458LG installed on this board in positions H501 thru H506 has a bad reputation as a potential source of noise. I replaced all 2SC458LGs with a modern low-noise Fairchild KSC1845 transistor. Watch the pinout on replacement transistors. The original transistor is BCE and the new one is ECB.

Tone amplifier board - before and after

Marantz_2215_Tone Amplifier Board (P500)_before servicing

Marantz_2215_Tone Amplifier Board (P500)_after servicing

Phono Amplifier Board (P900)

The phono amplifier board has 2 low leakage e-caps (C901, C902) installed in the input signal path, 2 solid tantalum capacitors (C905, C906), and 3 aluminum electrolytic capacitors (C909, C910, C919).

The original low leakage e-caps were replaced with film polyester WIMA MKS2 caps. Two solid tantalum capacitors were replaced with modern low leakage Nichicon UKL caps. And the remaining aluminum e-caps were replaced with low impedance Nichicon UPW/UPM caps.

Test results on original capacitors removed from the phono amplifier board:

C901: rated capacitance – 1uF, measured – 1uF, ESR – 3.41Ω, deviation: 0%
C902: rated capacitance – 1uF, measured – 1uF, ESR – 1.86Ω, deviation: 0%
C905: rated capacitance – 22uF, measured – 25uF, ESR – 0.62Ω, deviation: +14%
C906: rated capacitance – 22uF, measured – 26uF, ESR – 0.51Ω, deviation: +18%
C909: rated capacitance – 47uF, measured – 66uF, ESR – 0.48Ω, deviation: +40%
C910: rated capacitance – 47uF, measured – 65uF, ESR – 0.51Ω, deviation: +38%
C919: rated capacitance – 100uF, measured – 126uF, ESR – 0.18Ω, deviation: +26%

The original Toshiba 2SC1000 transistor installed in positions H901 to H904 often generates static noise in the circuit. I replaced all 2SC1000 transistors on this board with the modern low noise Fairchild KSC1845. The KSC1845 transistor has the same pinout as the Toshiba 2SC1000.

The original 2SC458LG transistor installed at positions H905 and H906 is also known to be a potential source of the noise. I replaced all 2SC458LGs with modern low noise Fairchild KSC1845 transistors. Watch the pinout on replacement transistors. The original transistor is BCE and the new one is ECB.

Phono amplifier board - before and after

Marantz_2215_Phono Amplifier Board (P900)_before servicing

Marantz_2215_Phono Amplifier Board (P900)_after servicing

Power Amplifier Board (P700)

The power amplifier board has 2 low leakage e-caps (C701, C702) installed in the input signal path, and 12 aluminum electrolytic capacitors (C703, C704, C707, C708, C709, C710, C711, C712, C715, C716, C717, C718). 

The original low leakage capacitors were replaced with film polyester WIMA MKS2 caps. The ordinary aluminum e-caps (C711 and C712) coupled between a pre-driver H701 (H702) and driver H703 (H704) transistor were replaced with modern low leakage Nichicon UKL caps to reduce the noise. The remaining aluminum capacitors were replaced with low impedance Nichicon UPW caps.

Two filter capacitors (C703 and C704) were glued to the board at the factory. I am not sure what type of glue was used, but it badly affected those capacitors. The rubber sealing completely dried out and has many microcracks. The positive terminal on each capacitor was rotted. Before installing new capacitors, I carefully removed the old adhesive from the board and cleaned the surrounding area with isopropyl alcohol.

Rotted leads on original filter capacitors C703 & C704

Marantz_2215_C703 & C704_positive lead is rotted

Test results on original capacitors removed from the power amplifier board:

C701: rated capacitance – 0.47uF, measured – 0.76uF, ESR – N/A, deviation: +62%
C702: rated capacitance – 0.47uF, measured – 0.61uF, ESR – N/A, deviation: +30%
C703: rated capacitance – 220uF, measured – N/A, positive terminal is rotted
C704: rated capacitance – 220uF, measured – N/A, positive terminal is rotted
C707: rated capacitance – 47uF, measured – 49uF, ESR – 0.16Ω, deviation: +4%
C708: rated capacitance – 47uF, measured – 48uF, ESR – 0.22Ω, deviation: +2%
C709: rated capacitance – 47uF, measured – 50uF, ESR – 0.18Ω, deviation: +6%
C710: rated capacitance – 47uF, measured – 50uF, ESR – 0.21Ω, deviation: +6%
C711: rated capacitance – 10uF, measured – 11uF, ESR – 0.92Ω, deviation: +10%
C712: rated capacitance – 10uF, measured – 12uF, ESR – 0.84Ω, deviation: +20%
C715: rated capacitance – 100uF, measured – 114uF, ESR – 0.34Ω, deviation: +14%
C716: rated capacitance – 100uF, measured – 105uF, ESR – 0.32Ω, deviation: +5%
C717: rated capacitance – 22uF, measured – 26uF, ESR – 0.26Ω, deviation: +18%
C718: rated capacitance – 22uF, measured – 27uF, ESR – 0.34Ω, deviation: +23%

All original trimming resistors (R723, R724, R729, R730) were replaced with new Bourns potentiometers. One original trimming resistor (R723) turned out to be faulty (open circuit). 

Power amplifier board - before and after

Marantz_2215_Power Amplifier Board (P700)_before servicing

Marantz_2215_Power Amplifier Board (P700)_after servicing

Power Transistors

The original power transistors were removed, cleaned, and tested with Atlas DCA55 semiconductor analyzer. The measured DC current gain on all transistors met the specifications in the datasheet. I mounted all the transistors back on the heat sink and applied fresh thermal paste. The old thermal pads were also replaced with new Mica ones.

FM Front End & AM Tuner Board (P100)

I didn't notice any problem with the tuner section in this receiver during the initial evaluation. However, due to the fact that all the controls in this unit were very dirty, it was quite difficult to pinpoint any particular issue. After I finished servicing all boards except the tuner section, I cleaned all the controls and tested the tuner again. I have noticed that the FM reception on this unit is not perfect. This could be improved upon the alignment of the tuner, but I chose to service the tuner section in this unit anyway due to the presence of many blue Panasonic e-caps. These capacitors do not age well and often deviate greatly from their capacitance rating. And, as you will see later, it was worth doing.

Please note that the FM Front End & AM tuner board cannot be serviced without being disassembled from the chassis. Make sure you have a new dial cord and be prepared to re-string the tuner.

The FM Front End & AM tuner board has 13 aluminum electrolytic capacitors (C105, C108, C112, C114, C118, C119, C121, C122, C128, C130, C131, C154, and C156). Nine of them are notorious blue Panasonic e-caps. I replaced all electrolytic capacitors on this board with low impedance Nichicon UPW caps. Note, that the e-cap C156 is soldered on the back (foil) side of the PCB.

The e-cap C156 is soldered on the back (foil) side

Marantz_2215_FM Front End & AM Tuner Board (P100)_C156

As can be seen below, all blue Panasonic capacitors are outside the capacitance tolerance of +/- 20%. Two of them (C105 & C108) drifted from their nominal capacitance by more than 100%!

Test results on original capacitors removed from the FM Front End & AM tuner board:

C105: rated capacitance – 10uF, measured – 25uF, ESR – 2.6Ω, deviation: +150% (!)
C108: rated capacitance – 10uF, measured – 34uF, ESR – 9.9Ω, deviation: +240% (!)
C112: rated capacitance – 10uF, measured – 14uF, ESR – 0.84Ω, deviation: +40%
C114: rated capacitance – 100uF, measured – 117uF, ESR – 0.21Ω, deviation: +17%
C118: rated capacitance – 10uF, measured – 15uF, ESR – 1.43Ω, deviation: +50%
C119: rated capacitance – 10uF, measured – 15uF, ESR – 1.18Ω, deviation: +50%
C121: rated capacitance – 10uF, measured – 14uF, ESR – 0.93Ω, deviation: +40%
C122: rated capacitance – 10uF, measured – 16uF, ESR – 1.17Ω, deviation: +60%
C128: rated capacitance – 220uF, measured – 222uF, ESR – 0.18Ω, deviation: +1%
C130: rated capacitance – 10uF, measured – 14uF, ESR – 0.77Ω, deviation: +40%
C131: rated capacitance – 10uF, measured – 14uF, ESR – 0.95Ω, deviation: +40%
C154: rated capacitance – 33uF, measured – 42uF, ESR – 0.62Ω, deviation: +27%
C156: rated capacitance – 220uF, measured – 258uF, ESR – 0.11Ω, deviation: +17%

The original e-cap C108 - the nominal capacitance is 10uF but the measured is 34uF

Marantz_2215_FM Front End & AM Tuner Board (P100)_C108

FM Front End & AM tuner board -before and after

Marantz_2215_FM Front End & AM Tuner Board (P100)_before servicing

Marantz_2215_FM Front End & AM Tuner Board (P100)_after servicing

FM IF Amplifier & Detector Unit (P200)

This board has 7 aluminum electrolytic capacitors: C203, C206, C210, C218, C225, C228, and C231. All of them were replaced with low impedance Nichicon UPW caps.

Again, all original e-caps from this board (blue Panasonic) drifted way out of the tolerance spec of +/- 20%. Some of them (C218, C228, and C231) drifted more than 100% from their nominal capacitance!

Test results on original capacitors removed from the FM IF amplifier & detector unit:

C203: rated capacitance – 10uF, measured – 17uF, ESR – 1.38Ω, deviation: +70%
C206: rated capacitance – 10uF, measured – 14uF, ESR – 0.82Ω, deviation: +40%
C210: rated capacitance – 10uF, measured – 17uF, ESR – 1.31Ω, deviation: +70%
C218: rated capacitance – 10uF, measured – 23uF, ESR – 2.4Ω, deviation: +130% (!)
C225: rated capacitance – 10uF, measured – 13uF, ESR – 0.96Ω, deviation: +30%
C228: rated capacitance – 10uF, measured – 28uF, ESR – 2.5Ω, deviation: +180% (!)
C231: rated capacitance – 10uF, measured – 45uF, ESR – 3.1Ω, deviation: +350% (!)

FM IF amplifier & detector unit - before and after

Marantz_2215_FM IF Amp & Detector Unit (P200)_before servicing

Marantz_2215_FM IF Amp & Detector Unit (P200)_after servicing

Muting Control & Meter Amplifier Unit (P300)

This board has only 3 aluminum electrolytic capacitors: C307, C308, and C309. I replaced them with low impedance Nichicon UPW/UHE caps.

Test results on original capacitors removed from the muting control & meter amplifier unit:

C307: rated capacitance – 33uF, measured – 36uF, ESR – 0.52Ω, deviation: +9%
C308: rated capacitance – 4.7uF, measured – 6.1uF, ESR – 1.81Ω, deviation: +30%
C309: rated capacitance – 10uF, measured – 12uF, ESR – 1.05Ω, deviation: +20%

Muting control & meter amplifier unit - before and after

Marantz_2215_Muting Control & Meter Amplifier Unit (P300)_before servicing

Marantz_2215_Muting Control & Meter Amplifier Unit (P300)_after servicing

MPX Stereo Decoding Amplifier Board (P400)

The MPX stereo decoding amplifier board has 3 low leakage e-caps (C432, C433, C434) and 13 aluminum electrolytic capacitors (C401, C402, C406, C408, C414, C415, C416, C417, C418, C419, C430, C431, and C435).

The original low leakage e-caps were replaced with WIMA MKS2 (C432, C433) and Kemet (C434) polyester film caps. The four ordinary aluminum e-caps (C417, C418, C430, C431) installed between the crosstalk canceling and buffer amplifiers were replaced with modern low leakage Nichicon UKL caps. The remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps. Pay attention to the polarity of e-cap C414. The polarity on the silkscreen is backward!

Test results on original capacitors removed from the MPX stereo decoding amplifier board:

C401: rated capacitance – 10uF, measured – 13uF, ESR – 0.91Ω, deviation: +30%
C402: rated capacitance – 10uF, measured – 14uF, ESR – 1.14Ω, deviation: +40%
C406: rated capacitance – 10uF, measured – 13uF, ESR – 1.26Ω, deviation: +30%
C408: rated capacitance – 220uF, measured – 241uF, ESR – 0.14Ω, deviation: +10%
C414: rated capacitance – 33uF, measured – 41uF, ESR – 1.14Ω, deviation: +24%
C415: rated capacitance – 10uF, measured – 14uF, ESR – 3.1Ω, deviation: +40%
C416: rated capacitance – 10uF, measured – 11uF, ESR – 1.08Ω, deviation: +10%
C417: rated capacitance – 10uF, measured – 14uF, ESR – 1.12Ω, deviation: +40%
C418: rated capacitance – 10uF, measured – 16uF, ESR – 1.18Ω, deviation: +60%
C419: rated capacitance – 220uF, measured – 242uF, ESR – 0.22Ω, deviation: +10%
C430: rated capacitance – 10uF, measured – 18uF, ESR – 1.51Ω, deviation: +80%
C431: rated capacitance – 10uF, measured – 17uF, ESR – 1.58Ω, deviation: +70%
C432: rated capacitance – 0.47uF, measured – 0.57uF, ESR – N/A, deviation: +21%
C433: rated capacitance – 0.47uF, measured – 0.53uF, ESR – N/A, deviation: +13%
C434: rated capacitance – 0.1uF, measured – 0.12uF, ESR – N/A, deviation: +20%
C435: rated capacitance – 100uF, measured – 111uF, ESR – 0.32Ω, deviation: +11%

MPX stereo decoding amplifier board - before and after

Marantz_2215_MPX Stereo Decoding Amplifier (P400)_before servicing

Marantz_2215_MPX Stereo Decoding Amplifier (P400)_after servicing

Dial and Meter Lamps

The old incandescent lamps were replaced with warm white LED lamps to maintain the original look and decrease heat. The original incandescent lamp behind the meter was also replaced with a warm white LED lamp. The old yellowish vellum behind the dial scale was replaced with new heavyweight vellum paper.

The old stereo indicator and dial pointer lamps were replaced with new incandescent lamps. 

Dial scale removed - original incandescent dial lamps

Marantz_2215_Dial Scale removed_original lamps

Dial scale removed - new LED lamps

Marantz_2215_Dial Scale removed_new LED lamps

Audio Adjustments 

To adjust a bias, connect the multimeter between pins J713 and J715, and adjust the trimming resistor R729 until the multimeter reads ~7.5mV DC. For the other channel, connect the multimeter between J714 and J716, and adjust the trimming resistor R730 for the same reading.

To adjust a clipping level, I connected my oscilloscope across the speaker terminals and applied a sine-wave signal of 1 kHz to the AUX jacks. The trimming resistor R723 was adjusted for equal and symmetrical clipping. For the other channel, the trimming resistor R724 was adjusted.

Bias on the left and right channels after restoration

Marantz_2215_Bias_left channel

Marantz_2215_Bias_right channel

Output Power Test

The final output power test was performed at the end of my restoration. The receiver was loaded with a low inductance 8Ω/100W dummy resistor for each channel. The oscilloscope was connected across the speaker terminals and a sine-wave signal of 1kHz was applied to the AUX jacks. The output sine-wave signal was perfectly symmetrical on both channels with no clipping up to 12.26 VRMS (left channel) and 12.26 VRMS (right channel). It corresponds to the output power of 18.8W on the left channel and 18.8W on the right channel.

Output power test

Marantz 2215_Output Power Test

As usual, all the knobs and the face plate were gently cleaned in warm water with dish soap. All controls have been cleaned with DeoxIT 5% contact cleaner and lubricated with DeoxIT FaderLube 5% spray.

The final result can be seen in the photos below. Please watch a short demo video at the end of this post. Thank you for reading.

Marantz 2215 - after restoration

Marantz_2215_after restoration

Marantz_2215_after restoration_with parts

Demo video after repair & restoration

Sunday, March 5, 2023

Marantz 4230 Receiver Restoration

Unit: AM/FM Stereo 2 + Quadradial 4 Receiver
Manufacturer: Marantz
Model: 4230
SN: 14880

Today I'm showcasing a Marantz 4230 vintage receiver that came in for restoration. The Marantz 4230 is a 4-channel quadraphonic receiver. It was introduced in 1973 and was on the market until 1978. It produces 30 watts per channel in stereo mode or 12 watts per channel in quadraphonic mode. The total harmonic distortion is less than 0.9%. The list price in 1974 was $499.95. The optional walnut veneer cabinet for this model is WC-22 and it was available for $29.95 (Ref. TEAM Electronics catalog, page 15).

Marantz 4230_after restoration

The Power Mode switch on the rear panel switches the receiver from 4-channel mode to 2-channel mode. Be aware not to use 4Ω speakers in 2-channel mode! The 4Ω speakers can be only used in 4-channel mode. Use only 8Ω speakers (or higher) in 2-channel mode. Also, be sure to never cycle the rear panel Power Mode switch with the unit turned on.

According to the factory stamp on the chassis, this unit was manufactured in December 1973.

Power Supply Board (P800)

The regulated power supply board provides +35V DC to all of the amplifiers (except main power amplifiers), and +14V DC to the tuner section. 

This board has 5 aluminum electrolytic capacitors: C801, C802, C803, C804, and C805. I replaced them with high reliability, low impedance Nichicon UPW/UPM caps.

The original e-caps were tested with an Atlas ESR70 capacitance meter, and the results are below. Note, that one capacitor C801 failed the test (open circuit/low capacitance).

Test results on original capacitors removed from the power supply board:

C801: rated capacitance – 3.3uF, measured – open circuit/low capacitance
C802: rated capacitance – 470uF, measured – 553uF, ESR – 0.11Ω, deviation: +18%
C803: rated capacitance – 330uF, measured – 405uF, ESR – 0.16Ω, deviation: +23%
C804: rated capacitance – 330uF, measured – 353uF, ESR – 0.06Ω, deviation: +7%
C805: rated capacitance – 470uF, measured – 498uF, ESR – 0.11Ω, deviation: +6%

I also replaced two original 2SC945 transistors installed in positions H802 and H803 with new Fairchild KSC945s.

After the servicing, the voltage between pin J801 and J811 (ground) was adjusted to +35.0V DC with trimming resistor R801.

Power supply board - voltage regulator adjustment

Marantz 4230_Power Supply Board (P800)_voltage regulator adjustment

Power supply board - before and after

Marantz 4230_Power Supply Board (P800)_before servicing

Marantz 4230_Power Supply Board (P800)_after servicing

Power Amplifier Board (P700 x 2)

Marantz 4230 has two power amplifier boards: front (left & right channels) and rear (left & right channels). Each board has 2 low leakage e-caps (C703, C704), 11 aluminum electrolytic capacitors (C702, C707, C708, C712, C713, C716, C717, C718, C719, C720, C721), and 2 coupling capacitors (C726, C727). The original low leakage e-caps were replaced with high-quality film polyester WIMA caps. The original coupling capacitors were replaced with Nichicon LKG caps (type II, Gold Tune).  The new coupling capacitors are designed for high grade audio equipment, giving priority to high-fidelity sound quality. They have the same diameter and lead spacing but are shorter than the original ones. The remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps.

Note, that one capacitor C712 installed in the front board (left channel) failed the test (open circuit/low capacitance).

Test results on original capacitors removed from the power amplifier board:

Front (left & right channels):
C702: rated capacitance – 47uF, measured – 54uF, ESR – 0.19Ω, deviation: +15%
C703: rated capacitance – 1uF, measured – 0.9uF, ESR – 4.5Ω, deviation: -10%
C704: rated capacitance – 1uF, measured – 1uF, ESR – 3.1Ω, deviation: 0%
C707: rated capacitance – 47uF, measured – 56uF, ESR – 0.11Ω, deviation: +19%
C708: rated capacitance – 47uF, measured – 56uF, ESR – 0.15Ω, deviation: +19%
C712: rated capacitance – 10uF, measured – open circuit/low capacitance
C713: rated capacitance – 10uF, measured – 11uF, ESR – 2.9Ω, deviation: +10%
C716: rated capacitance – 100uF, measured – 132uF, ESR – 0.32Ω, deviation: +32%
C717: rated capacitance – 100uF, measured – 128uF, ESR – 0.37Ω, deviation: +28%
C718: rated capacitance – 47uF, measured – 53uF, ESR – 1.88Ω, deviation: +13%
C719: rated capacitance – 47uF, measured – 54uF, ESR – 0.16Ω, deviation: +15%
C720: rated capacitance – 22uF, measured – 25uF, ESR – 0.38Ω, deviation: +14%
C721: rated capacitance – 22uF, measured – 25uF, ESR – 0.26Ω, deviation: +14%
C726: rated capacitance – 3300uF, measured – 3932uF, ESR – 0.03Ω, deviation: +19%
C727: rated capacitance – 3300uF, measured – 3886uF, ESR – 0.02Ω, deviation: +18%

Rear (left & right channels):
C702: rated capacitance – 47uF, measured – 53uF, ESR – 0.34Ω, deviation: +13%
C703: rated capacitance – 1uF, measured – 0.9uF, ESR – 3.9Ω, deviation: -10%
C704: rated capacitance – 1uF, measured – 0.9uF, ESR – 4.1Ω, deviation: -10%
C707: rated capacitance – 47uF, measured – 54uF, ESR – 0.15Ω, deviation: +15%
C708: rated capacitance – 47uF, measured – 56uF, ESR – 0.18Ω, deviation: +19%
C712: rated capacitance – 10uF, measured – 12uF, ESR – 2.1Ω, deviation: +20%
C713: rated capacitance – 10uF, measured – 11uF, ESR – 2.2Ω, deviation: +10%
C716: rated capacitance – 100uF, measured – 94uF, ESR – 0.66Ω, deviation: -6%
C717: rated capacitance – 100uF, measured – 123uF, ESR – 0.46Ω, deviation: +23%
C718: rated capacitance – 47uF, measured – 54uF, ESR – 1.11Ω, deviation: +15%
C719: rated capacitance – 47uF, measured – 46uF, ESR – 0.15Ω, deviation: -2%
C720: rated capacitance – 22uF, measured – 25uF, ESR – 1.91Ω, deviation: +14%
C721: rated capacitance – 22uF, measured – 25uF, ESR – 0.58Ω, deviation: +14%
C726: rated capacitance – 3300uF, measured – 3880uF, ESR – 0.04Ω, deviation: +18%
C727: rated capacitance – 3300uF, measured – 3826uF, ESR – 0.06Ω, deviation: +16%

Two driver transistors (H704 and H705) installed on the power amplifier board are Panasonic 2SC1318. This transistor is on my list of transistors that are prone to failure. I replaced each 2SC1318 with a modern Fairchild KSC2383. Note, that the original 2SC1318 transistor installed in position H705 (rear board, right channel) was toasted. It is still functional, but the measured current gain is only ~66, below the minimum value for this rank (rank Q, hfe = 85~170).

Toasted transistor 2SC1318 installed in position H705 (rear board, right channel)

Marantz 4230_Power amplifier Board (P700)_Toasted H705

Power amplifier board (front) - before and after

Marantz 4230_Power Amplifier Board (P700)_front (L&R)_before servicing

Marantz 4230_Power Amplifier Board (P700)_front (L&R)_after servicing

Power amplifier board (rear) - before and after

Marantz 4230_Power Amplifier Board (P700)_rear (L&R)_before servicing

Marantz 4230_Power Amplifier Board (P700)_rear (L&R)_after servicing

Power Transistors

According to the owner, this unit was serviced at a local repair shop around 1986-88. They replaced four of the original eight power transistors. The original power transistors installed in this unit are 2SC789 (package type TO-220) and the new transistors are 2SD315 (package type TO-66). Both transistors have similar parameters and are designed for use in audio frequency power amplifiers. In addition, the 2SD315 was officially recommended by Marantz as a replacement for the 2SC789 transistor (see Marantz Service Bulletin M-4230-3, August 19, 1975). So there are no questions here. However, using the same power transistors in both channels makes sense to ensure the same performance. So, I decided to replace all power transistors (H001 thru H004) with new OnSemi TIP41C transistors. The TIP41C transistor is designed for use in general-purpose amplifiers and has superior performance over the 2SC789 and 2SD315.

Power transistors (front) - before and after

Marantz 4230_Power Transistors_front (L&R)_before servicing

Marantz 4230_Power Transistors_front (L&R)_after servicing

Power transistors (rear) - before and after

Marantz 4230_Power Transistors_rear (L&R)_before servicing

Marantz 4230_Power Transistors_rear (L&R)_after servicing

Tone Amplifier Board (PE01)

The tone amplifier board has 20 low leakage e-caps (CE01, CE02, CE03, CE04, CE05, CE06, CE07, CE08, CE09, CE10, CE11, CE12, CE17, CE18, CE19, CE20, CE25, CE26, CE27, CE28) installed in the signal path and 5 aluminum electrolytic capacitors (CE13, CE14, CE15, CE16, CE29). The original low leakage e-caps with a rated capacitance of 1uF and lower were replaced with film polyester WIMA caps. The other low leakage e-caps were replaced with modern low leakage Nichicon UKL caps. And, the remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps.

Test results on original capacitors removed from the tone amplifier board:

CE01: rated capacitance – 4.7uF, measured – 4.6uF, ESR – 2.1Ω, deviation: -2%
CE02: rated capacitance – 4.7uF, measured – 4.7uF, ESR – 1.86Ω, deviation: 0%
CE03: rated capacitance – 4.7uF, measured – 4.6uF, ESR – 2.1Ω, deviation: -2%
CE04: rated capacitance – 4.7uF, measured – 4.5uF, ESR – 1.77Ω, deviation: -4%
CE05: rated capacitance – 0.47uF, measured – 0.42uF, ESR – N/A, deviation: -11%
CE06: rated capacitance – 0.47uF, measured – 0.43uF, ESR – N/A, deviation: -9%
CE07: rated capacitance – 0.47uF, measured – 0.43uF, ESR – N/A, deviation: -9%
CE08: rated capacitance – 0.47uF, measured – 0.46uF, ESR – N/A, deviation: -2%
CE09: rated capacitance – 1uF, measured – 1.1uF, ESR – 3.6Ω, deviation: +10%
CE10: rated capacitance – 1uF, measured – 1.1uF, ESR – 3.1Ω, deviation: +10%
CE11: rated capacitance – 1uF, measured – 1.1uF, ESR – 2.7Ω, deviation: +10%
CE12: rated capacitance – 1uF, measured – 1.0uF, ESR – 2.7Ω, deviation: 0%
CE13: rated capacitance – 10uF, measured – 13uF, ESR – 0.58Ω, deviation: +30%
CE14: rated capacitance – 10uF, measured – 13uF, ESR – 0.62Ω, deviation: +30%
CE15: rated capacitance – 10uF, measured – 13uF, ESR – 0.73Ω, deviation: +30%
CE16: rated capacitance – 10uF, measured – 13uF, ESR – 0.59Ω, deviation: +30%
CE17: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 1.73Ω, deviation: 0%
CE18: rated capacitance – 3.3uF, measured – 3.2uF, ESR – 1.26Ω, deviation: -3%
CE19: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 1.63Ω, deviation: 0%
CE20: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 1.67Ω, deviation: 0%
CE25: rated capacitance – 1uF, measured – 1.0uF, ESR – 3.8Ω, deviation: 0%
CE26: rated capacitance – 1uF, measured – 1.1uF, ESR – 2.8Ω, deviation: +10%
CE27: rated capacitance – 1uF, measured – 1.1uF, ESR – 2.6Ω, deviation: +10%
CE28: rated capacitance – 1uF, measured – 1.1uF, ESR – 2.8Ω, deviation: +10%
CE29: rated capacitance – 100uF, measured – 113uF, ESR – 0.08Ω, deviation: +13%

Tone amplifier board - before and after

Marantz 4230_Tone Amplifier Board (PE01)_before servicing

Marantz 4230_Tone Amplifier Board (PE01)_after servicing

Vari-Matrix Unit (P500)

The vari-matrix unit has 10 low leakage e-caps (C501, C502, C503, C504, C505, C506, C511, C512, C515, C516) installed in the signal path and 3 aluminum electrolytic capacitors (C513, C514, C521). The original low leakage e-caps with a rated capacitance of 0.47uF were replaced with film polyester WIMA caps. The other low leakage e-caps were replaced with modern low leakage Nichicon UKL caps. And, the remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps.

Test results on original capacitors removed from the vari-matrix unit:

C501: rated capacitance – 0.47uF, measured – 0.41uF, ESR – N/A, deviation: -13%
C502: rated capacitance – 0.47uF, measured – 0.44uF, ESR – N/A, deviation: -6%
C503: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 1.31Ω, deviation: 0%
C504: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 1.18Ω, deviation: 0%
C505: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 2.1Ω, deviation: 0%
C506: rated capacitance – 3.3uF, measured – 3.2uF, ESR – 1.22Ω, deviation: -3%
C511: rated capacitance – 3.3uF, measured – 3.3uF, ESR – 3.7Ω, deviation: 0%
C512: rated capacitance – 3.3uF, measured – 3.4uF, ESR – 1.87Ω, deviation: +3%
C513: rated capacitance – 100uF, measured – 181uF, ESR – 0.21Ω, deviation: +81%
C514: rated capacitance – 100uF, measured – 168uF, ESR – 0.22Ω, deviation: +68%
C515: rated capacitance – 3.3uF, measured – 3.2uF, ESR – 1.18Ω, deviation: -3%
C516: rated capacitance – 3.3uF, measured – 3.4uF, ESR – 1.32Ω, deviation: +3%
C521: rated capacitance – 100uF, measured – 93uF, ESR – 0.13Ω, deviation: -7%

Vari-matrix unit - before and after

Marantz 4230_Vari-Matrix Unit (P500)_before servicing

Marantz 4230_Vari-Matrix Unit (P500)_after servicing

Buffer Amplifier Board (PD01)

The buffer amplifier has 8 low leakage e-caps (CD01, CD02, CD03, CD04, CD05, CD06, CD07, CD08) and one aluminum electrolytic capacitor CD09. The original low leakage e-caps were replaced with modern low leakage Nichicon UKL caps. The aluminum e-cap CD09 was replaced with a low impedance Nichicon UPW cap.

I noticed some inconsistencies between the schematic and what was installed on this board. According to the diagram and parts list in the service manual, the 4 low leakage capacitors CD01 to CD04 should be 1uF/50V. However, the capacitors installed in these positions are rated at 4.7uF/25V. This board has not been previously serviced and everything looks original and pristine. So, I replaced them with Nichicon UKL low leakage 4.7uF/50V capacitors. Service manuals from that era are notorious for a lot of errors. I believe this was a minor modification during the production of this model and was not well documented.

Test results on original capacitors removed from the buffer amplifier board:

CD01: rated capacitance – 4.7uF, measured – 4.7uF, ESR – 1.78Ω, deviation: 0%
CD02: rated capacitance – 4.7uF, measured – 5.3uF, ESR – 1.56Ω, deviation: +13%
CD03: rated capacitance – 4.7uF, measured – 5.1uF, ESR – 1.11Ω, deviation: +9%
CD04: rated capacitance – 4.7uF, measured – 5.2uF, ESR – 0.93Ω, deviation: +11%
CD05: rated capacitance – 10uF, measured – 11uF, ESR – 0.74Ω, deviation: +10%
CD06: rated capacitance – 10uF, measured – 10uF, ESR – 0.93Ω, deviation: 0%
CD07: rated capacitance – 10uF, measured – 10uF, ESR – 1.31Ω, deviation: 0%
CD08: rated capacitance – 10uF, measured – 10uF, ESR – 0.76Ω, deviation: 0%
CD09: rated capacitance – 100uF, measured – 113uF, ESR – 0.21Ω, deviation: +13%

Buffer amplifier board - before and after

Marantz 4230_Buffer Amplifier Board (PD01)_before servicing

Marantz 4230_Buffer Amplifier Board (PD01)_after servicing

Phono Amplifier Board (P400)

The phono amplifier board has 4 low leakage e-caps (C401, C402, C411, C412) installed in the signal path and 3 aluminum electrolytic capacitors (C409, C410, C413). The original low leakage e-caps with a rated capacitance of 1uF were replaced with film polyester WIMA caps. The other low leakage e-caps were replaced with modern low leakage Nichicon UKL caps. And, the remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps.

Test results on original capacitors removed from the phono amplifier board:

C401: rated capacitance – 4.7uF, measured – 4.7uF, ESR – 1.35Ω, deviation: 0%
C402: rated capacitance – 4.7uF, measured – 4.3uF, ESR – 1.55Ω, deviation: -9%
C409: rated capacitance – 220uF, measured – 242uF, ESR – 0.14Ω, deviation: +10%
C410: rated capacitance – 220uF, measured – 249uF, ESR – 0.15Ω, deviation: +13%
C411: rated capacitance – 1uF, measured – 1.3uF, ESR – 1.9Ω, deviation: +30%
C412: rated capacitance – 1uF, measured – 1.3uF, ESR – 2.2Ω, deviation: +30%
C413: rated capacitance – 100uF, measured – 116uF, ESR – 0.38Ω, deviation: +16%

Phono amplifier board - before and after

Marantz 4230_Phono Amplifier Board (P400)_before servicing

Marantz 4230_Phono Amplifier Board (P400)_after servicing

400 Hz Oscillator & Meter Driver Board (PL01)

This board has 8 aluminum electrolytic capacitors: CL05, CL06, CL07, CL10, CL11, CL12, CL13, CL14. They have all been replaced with low impedance Nichicon UPW caps. Note that the e-cap CL14 is soldered on the back (foil) side of the PCB. Also, pay attention to the polarity of this cap. The schematic shows the correct polarity (the negative lead of CL14 is soldered to the ground) but the PCB layout in the service manual shows the wrong polarity.

Test results on original capacitors removed from the 400 Hz oscillator & meter driver board:

CL05: rated capacitance – 10uF, measured – 16uF, ESR – 4.3Ω, deviation: +60%
CL06: rated capacitance – 10uF, measured – 15uF, ESR – 2.8Ω, deviation: +50%
CL07: rated capacitance – 10uF, measured – 15uF, ESR – 3.1Ω, deviation: +50%
CL10: rated capacitance – 10uF, measured – 13uF, ESR – 5.4Ω, deviation: +30%
CL11: rated capacitance – 10uF, measured – 14uF, ESR – 4.8Ω, deviation: +40%
CL12: rated capacitance – 10uF, measured – 12uF, ESR – 5.6Ω, deviation: +20%
CL13: rated capacitance – 10uF, measured – 12uF, ESR – 5.4Ω, deviation: +20%
CL14: rated capacitance – 33uF, measured – 42uF, ESR – 0.23Ω, deviation: +27%

400 Hz oscillator & meter driver board - before and after

Marantz 4230_400 Hz Oscillator & Meter Driver Board (PL01)_before servicing

Marantz 4230_400 Hz Oscillator & Meter Driver Board (PL01)_after servicing

Dolby Unit (P600)

The Dolby unit has 2 low leakage e-caps (C601, C602) and 17 aluminum electrolytic capacitors (C607, C608, C609, C610, C611, C612, C613, C614, C623, C624, C627, C628, C631, C632, C635, C636, C641). The original low leakage e-caps were replaced with modern low leakage Nichicon UKL caps. And, the remaining aluminum e-caps were replaced with low impedance Nichicon UPW caps.

Test results on original capacitors removed from the Dolby unit:

C601: rated capacitance – 3.3uF, measured – 3.2uF, ESR – 2.9Ω, deviation: -3%
C602: rated capacitance – 3.3uF, measured – 3.0uF, ESR – 2.8Ω, deviation: -9%
C607: rated capacitance – 10uF, measured – 12uF, ESR – 5.1Ω, deviation: +20%
C608: rated capacitance – 10uF, measured – 12uF, ESR – 4.5Ω, deviation: +20%
C609: rated capacitance – 10uF, measured – 15uF, ESR – 3.2Ω, deviation: +50%
C610: rated capacitance – 10uF, measured – 15uF, ESR – 3.8Ω, deviation: +50%
C611: rated capacitance – 10uF, measured – 15uF, ESR – 5.1Ω, deviation: +50%
C612: rated capacitance – 10uF, measured – 13uF, ESR – 3.5Ω, deviation: +30%
C613: rated capacitance – 10uF, measured – 14uF, ESR – 5.0Ω, deviation: +40%
C614: rated capacitance – 10uF, measured – 15uF, ESR – 4.0Ω, deviation: +50%
C623: rated capacitance – 10uF, measured – 15uF, ESR – 4.2Ω, deviation: +50%
C624: rated capacitance – 10uF, measured – 13uF, ESR – 4.8Ω, deviation: +30%
C627: rated capacitance – 47uF, measured – 56uF, ESR – 0.57Ω, deviation: +19%
C628: rated capacitance – 47uF, measured – 54uF, ESR – 0.48Ω, deviation: +15%
C631: rated capacitance – 10uF, measured – 14uF, ESR – 4.6Ω, deviation: +40%
C632: rated capacitance – 10uF, measured – 13uF, ESR – 5.2Ω, deviation: +30%
C635: rated capacitance – 10uF, measured – 13uF, ESR – 5.0Ω, deviation: +30%
C636: rated capacitance – 10uF, measured – 15uF, ESR – 4.2Ω, deviation: +50%
C641: rated capacitance – 220uF, measured – 291uF, ESR – 0.09Ω, deviation: +32%

Dolby unit board - before and after

Marantz 4230_Dolby Unit (P600)_before servicing

Marantz 4230_Dolby Unit (P600)_after servicing

Dial and Meter Lamps

The old incandescent lamps were replaced with warm white LED lamps to maintain the original look and decrease heat. The original incandescent lamps behind two meters were also replaced with warm white LED lamps. The old yellowish vellum behind the dial scale was replaced with new heavyweight vellum paper.

Dial scale removed - original incandescent dial lamps

Marantz 4230_Dial scale removed_original incandescent lamps

Dial scale removed - warm white LED lamps

Marantz 4230_Dial scale removed_new warm white LED lamps

Additional Troubleshooting

Upon completion of the restoration, I ran into an additional problem. I was not able to adjust the bias in the right channel of the rear power amplifier board. The DC voltage between pins J718 and J712 was ~0.4V regardless of the position of trimming resistor R738. The trimming resistor R738 is shunted by diode H719. I tested both the trimming resistor and the diode, and the diode H719 was short. I replaced the original diode M8513A installed in position H719 with a new OnSemi 1N4448 but was still not able to adjust the bias. Further diagnostics showed that one of the two current-limiting transistors was faulty (H707, open base-emitter junction). I replaced both current-limiting transistors H707 and H709 with new OnSemi KSC945 and KSA992, respectively. Also, the original resistor R758 was toasted and replaced in the past, but a new resistor with the wrong resistance rating was installed (330Ω instead of 39Ω). I replaced this resistor with a new KOA Speer metal film resistor. After all these replacements, I was able to adjust the bias to ~15mV in this channel (see the next "Audio Adjustments" section). Yes, restoring a quadraphonic receiver can be a difficult task.

Audio Adjustments 

To adjust a bias, connect the multimeter between pins J717 and J711, and adjust the trimming resistor R737 until the multimeter reads ~15mV DC. For the other channel, connect the multimeter between J718 and J712, and adjust the trimming resistor R738 for the same reading.

To adjust a clipping level, I connected my oscilloscope across the speaker terminals and applied a sine-wave signal of 1 kHz to the CD-4/AUX jacks. The trimming resistor R727 was adjusted for equal and symmetrical clipping. For the other channel, the trimming resistor R728 was adjusted.

Bias on the left and right channels after restoration (front board)

Marantz 4230_Bias, front board, left channel

Marantz 4230_Bias, front board, right channel

Bias on the left and right channels after restoration (rear board)

Marantz 4230_Bias, rear board, left channel

Marantz 4230_Bias, rear board, right channel

Output Power Test

The final output power test was performed at the end of my restoration. The Power Mode switch on the rear panel was switched to the 4-channel mode. The receiver was loaded with a low inductance 8Ω/100W dummy resistor for each channel. The oscilloscope was connected across the speaker terminals and a sine-wave signal of 1kHz was applied to the AUX jacks. The output sine-wave signal was perfectly symmetrical on both channels (front and rear speaker terminals) with no clipping up to: 9.62 VRMS (front speakers, left channel), 9.75 VRMS (front speakers, right channel), 9.93 VRMS (rear speakers, left channel), and 9.84 VRMS (rear speakers, right channel). It corresponds to the output power of 11.6W (front speakers, left channel), 11.9W (front speakers, right channel), 12.3W (rear speakers, left channel), and 12.1W (rear speakers, right channel).

Output power test (front speakers)

Marantz 4230_Output power test (front speakers)

Output power test (rear speakers)

Marantz 4230_Output power test (rear speakers)

As usual, all the knobs and the face plate were gently cleaned in warm water with dish soap. All controls have been cleaned with DeoxIT 5% contact cleaner and lubricated with DeoxIT FaderLube 5% spray.

The final result can be seen in the photos below. This unit looks great and sounds wonderful. Please watch a short demo video at the end of this post. Thank you for reading.

Marantz 4230 - after restoration

Marantz 4230_after restoration

Marantz 4230_after restoration_with parts

Demo video after repair & restoration